Cosmos Week
The Simons Observatory: Analysis of methods for polarization calibration of multiple instruments
CosmologiaEdição em portuguêsPreprintResultado provisório

The Simons Observatory: Analysis of methods for polarization calibration of multiple instruments

Cosmic birefringence, the rotation of the CMB linear polarization plane across the Universe, is a powerful test of parity-violating physics beyond the Standard Model.

Fonte original citada e enquadrada editorialmente pelo Cosmos Week. arXiv Cosmology
Assinatura editorialRedação do Cosmos Week
Publicado23 nov 2026 18h59
Atualizado2026-11-23
Tipo de coberturaPreprint
Nível de evidênciaResultado provisório
Leitura4 min de leitura

Pontos-chave

  • Em foco: Cosmic birefringence, the rotation of the CMB linear polarization plane across the Universe, is a powerful test of parity-violating physics beyond
  • Detalhe: Resultado ainda sem revisão por pares
  • Leitura editorial: resultado provisório, ainda sem revisão por pares formal.
Texto completo

Cosmic birefringence, the rotation of the CMB linear polarization plane across the Universe, is a powerful test of parity-violating physics beyond the Standard Model. Static isotropic rotation, however, is limited by an instrument's absolute polarization-angle calibration.

We present a method for transferring absolute calibration between Simons Observatory (SO) instruments, validated on map-level simulations of the Large Aperture Telescope (LAT) and Small Aperture Telescopes (SATs) with lensed CMB polarization, polarized Galactic foregrounds.

We develop two pipelines: a joint LAT+SAT likelihood transferring calibration through their overlap, and the Minami-Komatsu foreground-based method, which separates cosmic birefringence from instrumental miscalibration using Galactic dust polarization without an external angle. We derive a general variance budget showing that calibration transfer improves sensitivity only when the combined reference and overlap transfer uncertainties remain below the receiving instrument's calibration uncertainty.

While transfer does not lower the absolute-angle floor for isotropic $β$, it anchors the receiving instrument's multipole range. The relative-angle uncertainty is $\sim 0.1^\circ$ for $\ell_{\max}^{\mathrm{SAT}}=300$, improving to $\sim 0.04^\circ$ at $\ell_{\max}^{\mathrm{SAT}}=600$, subject to SAT beam and transfer-function control.

Finally, for $β=0.3^\circ$, we show how the LAT's $\ell$-range distinguishes scale-independent dark-energy rotation from scale-dependent axion dark-matter models via $C_\ell^{EB}$. Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy.

ArXiv is committed to these values and only works with partners that adhere to them.

Fonte